Generator Sizing Calculator

What generator rating your loads need — running and starting watts with a safety margin, and the common size that covers both.

Inputs

Peak ÷ running: 1.9×

Results update as you type

Result

Required running rating
3,000 W
starting requirement 5,625 W
Suggested size
5,000 W generator
Assumes starting watts ≈ 1.25× running — verify on the datasheet.
Running requirement3,000 W
Starting requirement5,625 W
Load at suggested size48%
Generator size = running load × (1 + safety margin)
2,400 W × 1.25 = 3,000 W running · starting 4,500 W × 1.25 = 5,625 W
What this assumes
  • The running figure is everything that can run at once.
  • The peak figure includes the largest motor start on top of running loads.
  • Suggested sizes assume starting watts of about 1.25× the running rating.
  • Altitude and heat derating (~3% per 300 m) are not yet modelled.

Matching gear

No paid placements
5,000 W portable generatorStarting watts to verify: ≥ 5,625 W

The smallest common size that covers your running load with margin and the biggest motor start.

5,000 W inverter generatorClean sine output · quieter · usually parallel-capable

Worth the premium when laptops, CPAP machines or other sensitive electronics run on it.

These are generic product classes matched to your inputs, not brand endorsements. If retailer links are added in the future, they will be clearly marked as affiliate links.

Common size check

GeneratorLoad shareVerdict
2,000 W120%too small
3,200 W75%surge short
4,000 W60%surge short
5,000 W48%fits ✓
6,500 W37%fits ✓
8,000 W30%fits ✓
10,000 W24%fits ✓

Verdicts assume ~1.25× starting capability.

Questions

Running watts vs starting watts?

Generators carry two ratings: what they sustain continuously and what they deliver for a few seconds. Your loads have the same two numbers — match both.

Why not run a generator at 100% load?

Continuous duty near the limit shortens engine life and leaves nothing for starts. 50–80% load is the healthy operating band — the margin builds that in.

Do I need an inverter generator?

For laptops, CPAP machines and other sensitive electronics, yes — the clean sine output is worth it. For power tools and resistive loads, an open-frame unit is fine.

How the generator size is calculated

Add up everything that runs at the same time for the running load, and add the largest motor start on top of it for the peak. Both get a safety margin, giving the running rating the generator must sustain and the starting burst it must survive. For example, 2,400 W of running loads with an air-conditioner start peaking at 4,500 W and a 25% margin needs 3,000 W running and 5,625 W starting — a common 4,000 W unit covers the running side but falls short on starting, so the suggestion moves up to 5,000 W.

What the model leaves out

Two real-world effects are deliberately not modelled in v1. Altitude and heat derate engine output — roughly 3% per 300 m of elevation plus around 1% per 5 °C above 25 °C, so a mountain cabin needs the next size up. And fuel consumption varies too much between engines to estimate honestly; the manufacturer's half-load figure is the number to compare. Starting capability also differs by design — the suggestion assumes a typical 1.25× headroom, but the datasheet's starting-watts figure is the one that counts.

Generator plus battery is often smaller

A generator sized for the worst-case motor start idles oversized the rest of the time. Pairing a smaller generator with an inverter and battery bank lets the battery carry the surges and the generator run in its efficient band — size that system with the Inverter Sizing and Battery Bank Sizing calculators.

Methodology

The calculator UI, the size-check table and the displayed formula all call the same calculation function. Common sizes reflect the portable-generator market; the sources below carry the sizing conventions.

Sources for the default assumptions
  • Running vs starting watts sizing method — Generator manufacturer sizing guides (e.g. Honda, Generac, Champion)
  • Motor start-up draw of 2–6× running power — NEMA MG-1 motor locked-rotor code letters and appliance start-up specifications
  • Altitude/heat derating ≈ 3% per 300 m — Small-engine manufacturer derating guidance (carburetted engines)

Assumptions last reviewed on 27 August 2026. If a source disagrees with your battery or equipment datasheet, trust the datasheet.

Frequently asked questions

What is the difference between running and starting watts?

Running watts is what a generator sustains continuously; starting watts is the short burst it can deliver for motor start-up. Your loads have the same two numbers, and the generator must cover both.

Why should a generator not run at full load continuously?

Continuous duty near the rating shortens engine life, raises fuel use per kWh and leaves no headroom for the next motor start. 50–80% load is the healthy band — the safety margin builds that in.

When is an inverter generator worth the extra cost?

When sensitive electronics — laptops, CPAP machines, modern TVs — run on it. Inverter units produce a clean sine wave, run quieter and can usually be paralleled for more power.

Formula visibleThe equation is not a black box.
Assumptions editableUsers can change the margin freely.
One calculation sourceUI, examples and formula use the same model.
No account requiredCore tools work without signing up.